Morley DXC Fire Alarm Panel
Morley DXC Fire Alarm Panel
Morley DXC Fire Alarm Panel
Morley DXC Fire Alarm Panel
Morley DXC Fire Alarm Panel
Morley DXC Fire Alarm Panel

Morley DXC Fire Alarm Panel

Price 100000 INR/ Unit

MOQ : 1 Unit

Morley DXC Fire Alarm Panel Specification

  • Working Temperature
  • 0C to 40C
  • Technology
  • Advanced microprocessor-based addressable panel
  • Shape
  • Rectangular
  • Coverage Area
  • Depends on system design and number of devices
  • Control Type
  • Automatic and Manual
  • Voltage
  • 230V AC, 50/60Hz
  • Connectivity Type
  • Networkable, RS485, USB, Printer port
  • Mounting Type
  • Surface or flush mounting
  • Coating Type
  • Powder-coated metal enclosure
  • Installation Type
  • Wall mounting
  • Features
  • Expandable up to 8 loops, large graphical LCD display, event log, user-friendly interface, USB port for programming, programmable relays
  • Application
  • Fire detection and alarm system for commercial and industrial buildings
  • Capacity
  • 1, 2, 4, or 8 loops (up to 198 devices per loop)
  • Protocol
  • Morley-IAS protocol
  • Programming
  • PC programmable via USB
  • Loop Capacity
  • Expandable from 1 up to 8 loops (with optional modules)
  • Event Log Capacity
  • Up to 1000 events
  • Number of Zones
  • Multiple - configurable via software
  • Compliance Standard
  • EN54-2 and EN54-4 certified
  • Sounder Circuits
  • 2 onboard, expandable with modules
  • Display Type
  • Graphical 8-line LCD (40 characters per line)
  • Dimensions
  • 388 mm x 388 mm x 90 mm
  • Weight
  • 5.1 kg (approx.)
  • Panel Expandability
  • Expandable using network cards
  • Battery Backup
  • 24V DC from external batteries
 

Morley DXC Fire Alarm Panel Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 1 Unit Per Week
  • Delivery Time
  • 1 Week
  • Main Domestic Market
  • All India
 

About Morley DXC Fire Alarm Panel



The Morley DXC Fire Alarm Panel stands out as a top choice in fire safety technology, featuring a special rate for high-demand installations. Renowned for its classic and noteworthy design, this gorgeous panel boasts an easy-to-read graphical 8-line LCD display and records up to 1,000 events. Engineered for flexibility, it is programmable via USB and supports up to 8 addressable loops using the advanced Morley-IAS protocol. With compliance to EN54-2 and EN54-4 standards, robust battery backup, and expandable network connectivity, the DXC panel is ideal for modern commercial and industrial settings.

Superior Competitive Edge And Versatile Applications

The Morley DXC Fire Alarm Panel is valued for its primary competitive advantages such as scalability, a user-friendly interface, and comprehensive event logging. Its classic powder-coated finish offers durability for commercial and industrial environments. Specially designed for fire detection and alarm systems in large facilities, this panel excels in sites requiring multi-zone management and high device capacity, representing an optimal choice for both retrofit projects and new installations.


Domestic Market, Export Reach, And Secure Packaging

Serving the main domestic market across India, the Morley DXC Fire Alarm Panel is also exported to several international locations via reliable transportation networks, ensuring swift and safe goods transport. Each unit is carefully packaged in sturdy materials to prevent transit damage. By offering the lowest price among top suppliers and traders, this panel is widely accessible for bulk and single-unit buyers seeking exceptional value and reliability.


FAQ's of Morley DXC Fire Alarm Panel:


Q: How does the Morley DXC Fire Alarm Panel support system expansion?

A: The Morley DXC can be expanded from 1 up to 8 detection loops by adding optional modules and network cards, allowing for greater coverage and more connected devices as building requirements grow.

Q: What are the specific benefits of the graphical 8-line LCD display?

A: The graphical 8-line LCD offers clear, real-time information on system status, alarms, and events, supporting up to 40 characters per line. This makes monitoring and controlling complex fire safety systems simple and efficient.

Q: Where can the Morley DXC Fire Alarm Panel be installed?

A: This panel is ideal for commercial and industrial buildings. Its flexible mounting options (surface or flush) and robust enclosure make it suitable for various environments where reliable fire detection is essential.

Q: What is the process for programming the Morley DXC panel?

A: Programming is done via PC using a USB connection. The user-friendly interface allows for software-based configuration of zones, devices, and relays, ensuring adaptability to any site requirements.

Q: When should the battery backup be tested or replaced?

A: Battery backup should be tested at regular maintenance intervals, typically every six months. Replacement depends on battery condition and manufacturer recommendations to ensure uninterrupted panel operation during power failures.